EFFICIENT AND COST EFFECTIVE SOLUTION FOR ENHANCED REMOVAL OF
OFFENSIVE ODOURS, CORROSIVE AND POLLUTING GASES & VAPOURS SUCH AS
SULPHUR DIOXIDE, CHLORINE, HYDROGEN SULPHIDE, OZONE, NITROGEN OXIDES, MERCAPTANS, MERCURY,
ETC.
FEATURES
Filter media, impregnated activated carbon
for high single pass efficiency
Filter units with multiple panels providing;
Large Filteration
Area
High Dwell Time
Low Pressure drop
Large quantity of adsorbent to ensure long
operative life
Multiple units can be easily combined for
higher flow rates
Highly efficient sealing
mechanisms incorporated into frames to eliminate risk
of air bypass
APPLICATIONS
Chemical Process Industries
Fertilizer
Pulp & Paper
Acids and alkalies
Refineries
Food Processing
Sewerage Installations
Airports
Hospitals
Museums
Libraries
Kitchens
Toilets
Filter units with Pre-Filters, Fine-Filters, Activated
carbon filters in single & multiple sets are offered as per customer's requirements.
SPECIFICATION OF STANDARD
MODELS :
Part No.
DIMENSIONS
FILTER Panels
PERFORMANCE AT VEL=2.5 M/S
PERFORMANCE AT VEL=1.0 M/S
PERFORAMCNE AT VEL=0.1 M/S
W
H
D
NO.
THK
CMH
P.D.
D.T.
CMH
PD
D.T.
CMH
PD
D.T.
PF-1923
610
610
345
8
15
3349
26
0.03
1340
10
0.07
134
1
0.68
PF-1924
610
610
345
12
15
3349
12
0.04
1340
5
0.1
134
0
1.02
PF-1917
610
610
345
8
25
3349
48
0.05
1340
19
0.11
134
2
1.13
PF-1918
610
610
345
12
25
3349
22
0.07
1340
9
0.17
134
1
1.7
PF-1919
610
610
345
8
50
3349
103
0.09
1340
41
0.23
134
4
2.26
PF-1925
610
610
650
8
15
3349
9
0.05
1340
4
0.13
134
0
1.28
PF-1926
610
610
650
12
15
3349
5
0.08
1340
2
0.19
134
0
1.92
PF-1920
610
610
650
8
25
3349
17
0.09
1340
7
0.21
134
1
2.13
PF-1921
610
610
650
12
25
3349
8
0.13
1340
3
0.32
134
0
3.2
PF-1922
610
610
650
8
50
3349
31
0.17
1340
12
0.43
134
1
4.26
*Dimension 'D'
does not include gaskets
*All
dimensions are in MM
*CMH = Cubic Meter Per Hour
*P.D. = Presure drop in MM of
Water Column
*D.T.= Dwell time in Seconds
Standard filters are with GI frame. Stainless Steel, Aluminium
parts available on request.
Efficiency and operating life depends on operating
parameters for example a dwell time of 0.5 sec. with 1ppm chlorine gives efficiency of
more than 95% and will last for about 1800 operating hours, two stage filtration gives
more than 99.5% efficiency.
For high efficiency and long life of carbon filter
relative humidity should not exceed 60% and air should be free from oil and dust.